Oratech Controls, Inc.

 
   
   
   
Antx Telephone Alarm Dialers


A leading supplier of systems for remote asset monitoring, control, data logging and automatic alarm notification throughout the world. Our products are designed and manufactured to perform at the highest levels of reliability in the most demanding industrial and commercial markets. We have thousands of successful installations, many of which have been in operation for over 12 years.

 

DiaLog Elite

State-of-the-art Automatic alarm notification system ... with Web-enabled capabilities!

World's First Digital Voice Dialer

The ADAS DiaLog was the world's first digital voice synthesized alarm dialer. Today, we continue that heritage with the most user-friendly, robust unit on the market. Through the years, customer-required features have been added allowing the DiaLog to be used in numerous industries.

The DiaLog Elite is the industry's first Web-based, completely field-upgradable alarm dialer. It is a complete voice notification device that addresses all your monitoring and control requirements.

Easily customizable, the Elite can be configured with any combination of digital and analog inputs and relay outputs to match you specific needs. And, depending on your operating environment, it can be configured to work on or off the Web!

The Elite features a host of powerful options that can be installed in the field or downloaded over the phone line - you can even receive an upgrade to your system over the phone.

Best of all, because it's Web-based, the Elite will easily meet your growing needs today and far into the future.

Powerful built-in function that help our system function more powerfully

  • Continuous monitoring of up to 48 dry contact, digital or analog inputs in any combination.
  • Complete programming locally through the keypad,  remotely via phone or over the Internet.
  • remote alarm notification via phones, cell phones, pagers, alpha-pagers, fax and e-mail.
  • All options are field upgradeable without returning the  unit to the factory.
  • Alarm on the conditions you need to: contact settings, specific values, total durations, accumulations or rates of change
  • Input channels can control individual relays, giving you  complete control of what happens when different conditions occur.
  • Pre-programmed message or user can program his/her own specific messages

  

The DiaLog Elite grows as your needs do.

The Elite offers several methods for programming: Locally via the keypad
Remotely over a phone
Worldwide over the Internet

Different types of inputs and outputs: From 4 to 48 Dry Contact or Digital Inputs
From 8 to 48 Analog Inputs
From 4 to 24 8A Relays

 

Alarm types that match all your requirements: Contact Open or Close
Pulse totalization
Total time in a condition
Exceeding a high analog limit
Exceeding a low analog limit
Exceeding a positive rate of change
Exceeding a negative rate of change

Local notification of alarm conditions: LEDs change to red and blink to indicate in alarm.
Relays can be activated for any channel
The display shows all channels in alarm and their value.

Remote notification of alarm conditions: Call-out to a phone or cell-phone
Numeric messages on display pagers
Alphanumeric messages on alpha-pagers
Current status on the Internet
Faxed status reports
e-mail status reports

Quality constructed for maximum performance.

No alarm system is reliable unless it has been designed to be reliable. The Elite is unsurpassed in this area.

  • The Elite is mounted in a NEMA-4X enclosure to endure extreme exposure to the elements.
  • All field wiring uses pluggable connections, making it very easy for installation and de-installation.
Elite I/O cards
  • With the Elite, the user has no more fuses to replace in the event of lightning or power spikes. All inputs are electronically protected using solid-state automatic resettable fuses.
  • All digital and dry contact inputs are protected to withstand a constant 240V input, a frequent occurance during hurried installations. This allows the Elite to keep on working, even if wiring is not initially correct.

We even built in maintenance accountability.

If you cannot determine what caused an alarm or who acknowledged an alarm, what good is it to have an alarm system? The Elite keeps track of what you really need to know about the operation of your systems.

  • A 1000 entry event log stores all alarms, acknowledgements, call-outs, call-ins, and changes to programming. Each entry is time-stamped to provide a complete chronological trail of everything that has happened. This log can be printed locally to a parallel printer or uploaded to the Internet.
  • A Caller-ID function records all calls into the Elite. Any calls into the Elite for programming changes or acknowledging alarms is recorded in the event log with the Caller ID.
  • Any time a person changes the programming in the Elite, a copy can be sent automatically to a database on the Internet. The database provides a complete history of changes that have been made to the Elite.


 

 ...IT'S NOT just ANOTHER autodialer

The ADAS DiaLog was the world's first digital voice synthesized alarm dialer. Today, we continue that heritage with the most user-friendly, robust and cost effective unit on the market.

The DiaLog Scout is a small, industrial alarm notification and remote monitoring system. It provides monitoring from either 4 or 8 digital inputs, 2 analog inputs and can have a relay for control of blowers, fans, pumps, horns, etc.

The easy-to-use DiaLog Socut provides a low-cost solution to remote monitoring that is dependable and reliable - everything you want in an alarming and notification system with the same performance that you expect from an Antx product.

It's not just another autodialer! Unique features of the DiaLog Scout include local and remote programming, remote relay control, monitoring of digital and analog inputs, user programmable voice messages and internal battery backup. The Scout even calls you when its time to replace the battery - so you will not miss those critical alarms when the power goes out. Extensive solid-state protection is provided on the power, phone and all input lines so you do not have to replace fuses in the event of power surges or lightning hits.

The DiaLog Scout also is available as an OEM product that offers additional analog I/O, serial communication and modem communication.

 
Useful features to make your life easier


  • Features

    Integral keypad
    LCD display
    Panel or flush mount
    Listen-In capability
    Event log
    Textual channel names so you know exactly what channel is in alarm
    Pre-programmed or user-spoken messages for unique alarm notification for each condition

  • Alarm Notification

    Phone, cell phone or pager
    User-recorded messages for each input
    8-phone numbers to call on alarm
    Power fail alarm
    Low battery level alarm
    Local notification of alarm conditions

  • Remote Operations

    Call-in for status
    Call-in to acknowledge alarms
    Call-in to program phone numbers and channels
    User control of relay (DS11 model)

  • Options

    NEMA 4X enclosure
    Cell phone

Performance like you want it


  • Physical Characteristics

    Pluggable connectors
    9-15VDC at 300ma
    12-hour internal backup battery (included)
    Aluminum enclosure - 9.34"W x 7.22"H
    Operating temperature - 0-70C (32-158F)

  • Programming made simple

    All programming options are conveniently presented on the LCD display so you can select them using the keypad.
    For the novice user, options are presented one after another making it easy to setup and modify.
    For the experienced user, go directly to the option you want to change.
    Conveniently located on the front panel are the microphone for recording and the speaker for playing back messages.
    Historical events including all alarms, call-outs, relay controls, and acknowledgements are stored in the Event Log which can be retrieved locally or remotely.

  • Alarms being monitored

    Dry contract or digital inputs may be monitored for on/off conditions.
    Analog inputs may be monitored for high and/or low conditions.
    Power failure and low battery are always monitored by the DiaLog Scout.

  • System status

    System status can be obtained locally from the front panel or remotely over the phone.

  • Relay control

    The relay on the DS11 model can be automatically controlled when any individual or group of channels go into the alarm condition. It can even be activated on a high level and deactivated on a low level. Additionally, users can call-in to turn the relay on or off.





©2003 Oratech Controls, Inc.. All rights reserved.